Full and overload measuring device type AKAL 1
|
Technical Data |
|
Input signal |
4 ... 20 mA DC |
Input resistance |
100 to 300 Ohm |
Output:
3 pcs. isolated Relay contacts |
LED-signalling |
Switching voltage |
max. 48 V DC oder AC |
Switching current |
max. 0,5 A |
Switching power |
max. 10 W/VA |
Supply voltage |
24 V DC |
Supply range |
20,4 ... 27,6 V DC |
Current consumption |
ca. 80 mA |
Ambient temperature range |
0 °C to 40 °C |
|
Short description
The full and overload measuring device type AKAL 1 is for universal use e.g. for elevators to get their normal load,
full load and overload.
There are three relay contacts with electrical isolation to get three different
load conditions e.g. normal load (or empty load), full load and overload.
The input signal is the standard signal 4..20 mA e.g. from our
load cell type 180.
See also
datasheet
AKAL1 (Acrobat Reader, 24 KB).
|
|